Four typical scenarios that come up again and again in second- and third-level support for EV chargers – and how I approach them.

These examples are synthetic: they describe typical scenarios, not customer projects. I do not name customers or fleets; manufacturers are mentioned for description only.

01 Typical scenario, not a customer reference

Intermittent offline periods with cellular connectivity

Situation
An EV charger with a cellular connection keeps dropping offline in the backend for a few minutes. On site there is never a visible fault; a reboot helps, but not for long.
Possible causes
  • Keepalive: heartbeat or WebSocket ping is sent too rarely to keep the connection open.
  • The NAT timeout in the mobile network is shorter than the interval at which the charger sends data.
  • The modem firmware loses the data connection without the charge controller noticing.
Approach
Correlate heartbeat gaps in the backend with device logs and modem status messages, separate patterns by network, time of day and firmware version, vary keepalive parameters in a targeted way.
Result
An evidenced root cause – for example a keepalive interval that is too long relative to the NAT timeout – with a containment action via configuration and a permanent corrective action in the firmware.
02 Typical scenario, not a customer reference

The charger works with backend X, but not with backend Y

Situation
A charge point works flawlessly with one backend. With a second backend it connects but never starts a transaction – or is not even accepted.
Possible causes
  • BootNotification is rejected or remains in “Pending” status.
  • Negotiation of the WebSocket subprotocol (OCPP version) fails.
  • Configuration keys or field formats differ from what the second backend expects.
Approach
Put the message flows with both backends side by side, check deviations against the OCPP specification, compare configurations.
Result
A list of deviations with a clear assignment: what changes in the firmware, what in the backend configuration?
03 Typical scenario, not a customer reference

Signed meter values are rejected after a firmware update

Situation
After a firmware update, the backend or the transparency software rejects the signed meter values. Charging sessions can no longer be billed.
Possible causes
  • The public key has changed or is transmitted to the backend differently.
  • Format or encoding of the OCMF records has changed.
  • Timestamps or time zone differ.
Approach
Compare OCMF records before and after the update, verify signatures against the registered public key, trace how the key reaches the backend.
Result
A clear statement of whether the charger, the update process or the backend configuration needs to change – and which existing records are affected.
04 Typical scenario, not a customer reference

Charging profiles are ignored after a reboot (§ 14a EnWG)

Situation
The grid operator limits the power. After a reboot, the vehicle charges at full power again until the backend resends the charging profile.
Possible causes
  • Charging profiles are not stored persistently.
  • Validity period or stack level of the profile do not match.
  • After start-up, the transaction begins before the profile is active again.
Approach
Analyse the timing of the boot sequence and charging profile messages, compare the behaviour with the OCPP specification and the requirements of § 14a EnWG, reproduce in a test setup.
Result
An evidenced root cause with actions for the firmware and the backend configuration.

What does a report look like?

A synthetic sample 8D report shows structure and level of detail, using the offline periods as an example.

See the sample 8D report

Send me your toughest open case.

Describe the failure pattern and the systems involved. You will receive an acknowledgement with follow-up questions.